Cubes, Sliders and Rings
Showing 40 products
91017
Olympus CK40
Exciter (x) = 25mm, Emitter (m) = 20mm, Beamsplitter = 21x29mm. **Recommend installation at Chroma to ensure proper gluing.
91015
Zeiss Axio screws into turret
Exciter (x) = 25mm, Emitter (m) = 25mm, Beamsplitter = 25.5x36mm.
91013
Zeiss Axioline 6FL Slider
Exciter (x) = 25mm, Emitter (m) = 25mm, Beamsplitter = 25.5x36mm. Zeiss Axio 6FL has openings for 6 filters.
91012
Zeiss Axioline 5FL Slider
Exciter (x) = 25mm, Emitter (m) = 25mm, Beamsplitter = 25.5x36mm. Zeiss Axio 5FL has openings for 5 filters
91011
Zeiss Axioline 4FL Slider
Exciter (x) = 25mm, Emitter (m) = 25mm, Beamsplitter = 25.5x36mm. Zeiss Axio 4FL has openings for 4 filters
91009
Leica DMIRB Filter Cube
Exciter (x) = 20mm, Emitter (m) = 20mm, Beamsplitter = 22x27mm. **Recommend installation at Chroma to ensure proper gluing and alignment.
91007
Leica DM Filter Cube
Exciter (x) = 21.9mm, Emitter (m) = 23.4mm, Beamsplitter = 22x29mm. **Recommend installation at Chroma to ensure proper gluing and alignment.
91006
Zeiss Axioline 3FL Slider
Exciter (x) = 25mm, Emitter (m) 25mm, Beamsplitter = 25.5x36mm.
91005
Leica Aristoplan Filter Cube
Exciter (x) = 20mm, Emitter (m) = 20mm, Beamsplitter = 19x28mm. **Recommend installation at Chroma to ensure proper gluing and alignment.
91004
Leica Ploempak
Exciter (x) = 18mm, Emitter (m) = 18mm, Beamsplitter = 26mm. **Recommend installation at Chroma to ensure proper gluing and alignment. However, Chroma can only align Ploem cubes with 3 screws. Those with 4 screws must be sent to Leica.
91003
Olympus IMT2 Filter Cube
**Recommend installation at Chroma to ensure proper gluing and alignment.
91002
Olympus BH2
Exciter (x) = 20mm, Emitter (m) 20mm with a 2.5mm maximum thickness, Beamsplitter = 19x28mm. **Recommend installation at Chroma to ensure proper gluing and alignment.
91001
Nikon Eclipse/Quadfluor
This metal cube is also compatible with Nikon's E400, E600, E800 and E1000 upright microscopes, as well as the TE200 and TE300 inverted Eclipse microscopes. Please note that this Eclipse/Quadfluor cube is NOT intended for use in Nikon's Eclipse TE2000 or TI2000 microscopes and should not be confused with the 91020 cube. Users should also note that early versions of Diaphot microscopes used our 91000 (18mm) cubes, but many have been converted in order to be consistent with all later Diaphot models, which use this 91001 cube. Please contact your Nikon dealer to purchase this cube empty, or mounted with the following Chroma filter sets: 19000, 19001, 19002, 19004, 19012, 39000, 39001, 39002, 39003, 39004, 39005, 39007, 39010, 31021, 49028, 59001, 59004, 59022, 69000, 69002 **Recommend installation at Chroma to ensure proper gluing and alignment.
91000
18mm Nikon Microscopes (Diaphot, TMD)
Exciter (x) = 18mm, Emitter (m) = maximum thickness of 3.5mm, Beamsplitter = 18.26mm. **Recommend installation at Chroma to ensure proper gluing and alignment.